Replacement amalgam separation cartridge for the old-style of SolmeteX Hg5 amalgam separation system (#AL-50) only. This is NOT for the new-style of NXT systems.
Product Details:
- Filter lasts six months, based on ten operatories at full-time use
- The Hg5 amalgam separator is a Type 2 device with a maximum flow rate of 1000 ml/min and maximum fillable volume of 950 ml
- Filter is ISO 11143 Certified at 99.85%
- Two year warranty
Filter changes out in seconds! With the vacuum system still running, remove the full amalgam separation cartridge from the Hg5 unit. First, support the collection container with one hand, while removing the retaining pins with the other hand. Then, tilt the collection container to the side to release the vacuum and pull down to remove the cartridge.
Install new amalgam separation cartridge with the vacuum system still running still. Note the alignment of the fittings on the cartridge with the receiver holes in the upper unit. Then, gently insert the fittings into the receiver holes by rocking the container slightly.
The o-rings on the fittings should seat easily into the upper unit receivers. Next, push the amalgam separation cartridge into the upper unit until it is fully seated. Finally, insert the retaining pins into their correct holes unitl seated. You are now ready to go!
Includes: pre-paid mailer for disposal.
NOTE: Ships from the manufacturer. Please allow an additional 3-5 days processing time. If returned, there is a 15% restocking fee. At this time, this cannot ship to Canada.
Cartridge Installation Instructions (PDF)
Replacement amalgam separation cartridge for the old-style of SolmeteX Hg5 amalgam separation system (#AL-50) only. This is NOT for the new-style of NXT systems.
Product Details:
- Filter lasts six months, based on ten operatories at full-time use
- The Hg5 amalgam separator is a Type 2 device with a maximum flow rate of 1000 ml/min and maximum fillable volume of 950 ml
- Filter is ISO 11143 Certified at 99.85%
- Two year warranty
Filter changes out in seconds! With the vacuum system still running, remove the full amalgam separation cartridge from the Hg5 unit. First, support the collection container with one hand, while removing the retaining pins with the other hand. Then, tilt the collection container to the side to release the vacuum and pull down to remove the cartridge.
Install new amalgam separation cartridge with the vacuum system still running still. Note the alignment of the fittings on the cartridge with the receiver holes in the upper unit. Then, gently insert the fittings into the receiver holes by rocking the container slightly.
The o-rings on the fittings should seat easily into the upper unit receivers. Next, push the amalgam separation cartridge into the upper unit until it is fully seated. Finally, insert the retaining pins into their correct holes unitl seated. You are now ready to go!
Includes: pre-paid mailer for disposal.
NOTE: Ships from the manufacturer. Please allow an additional 3-5 days processing time. If returned, there is a 15% restocking fee. At this time, this cannot ship to Canada.
Cartridge Installation Instructions (PDF)