Handpiece Torque & Bur Retention
Guide walks you through the most common handpiece torque and bur retention problems, what causes them, and exactly how to fix them in this practice tip.
New site. Same people, same number, and the Tech Desk now answers 24/7.
Built on forty years of our technicians' answers. A technician by phone, Mon–Fri 7a–6p CT.
Knowledge center
Practice Tips, Quick Tips, how-to guides and technical Q&A from our technicians. Search by problem or browse by subject.
Guide walks you through the most common handpiece torque and bur retention problems, what causes them, and exactly how to fix them in this practice tip.
Dental instrument downtime doesn't just cost money -it costs chair time, rescheduled patients, and staff frustration. Most guides on "den...
Handpiece is leaking? It might not be your handpiece at all. Check these things before you replace your handpiece.
Summer is the perfect time to service your dental equipment. Here are 5 maintenance jobs — sterilizers, waterlines, handpieces, and more ...
Everything you need to know to select the perfect air/water syringe for you.
Advantages of RapidHeat™ sterilization begins with a commitment to patient safety — an essential priority in every dental practice. Given...
So you have a cuspidor on your delivery unit? Because of this, the cuspidor drain kit is an integral and necessary connection for your sy...
Keep your junction box and delivery unit up and running with the help of these repair parts. This will help you diagnose the parts to che...
Dental Lab Equipment Basics So you want to set-up a dental lab at your practice, but don't know the essential equipment needed? It is imp...
Create a new efficient and functional operatory with the required equipment that makes your practice optimal for patient care. Dental tec...
Pick the equipment, then what it's doing. See the likely cause and the part that fixes it.
A turbine that screams, slows under load or lets the bur wobble has worn bearings. Swapping it is a bench job — try the Bench Trainer below first.
The gasket between the handpiece and the tubing connector flattens with use and starts to leak.
A repair kit replaces the buttons and seals. On DCI push-collar syringes, push the pin out and the buttons come right out.
The toggle is a separate part. Replace it and keep the foot control.
Crusting at a position means leaking o-rings have seized the stem; no water at a position is usually a failed cartridge or diaphragm. The kit rebuilds both.
Start chairside: check the trap and the canister basket before anything bigger.
Levers pop off for cleaning. Clean, lube with silicone lubricant (#03-40) and snap back on — or replace.
A flattened or cracked gasket lets steam out and cycles fail. The door dam (#DG-36) is sold separately.
The seal lives in the cassette lid. Cool and separate the cassette first; a gasket tool (#DG-100) makes removal easier.
The M11/M11D preventive maintenance kit. The M9/M9D kit is #MR-71.
Match the wattage, voltage and pins. This one is the 150W 24V two-pin bulb, A-dec OEM #041.279.02.
Free to print. Keep them by the equipment.
Instrument lists from the Hands-On Extraction course.